Why Your Alarm List Is Full and Nobody Checks It
When every alarm looks urgent, people stop checking them. A useful list shows how serious it is and how long the point has been out of limit.
Nick Nenno·Founder, Setpoint
When the alarm list is full, people stop reading it. Most of those limits were entered at startup, and nobody went back and deleted the ones that never needed a response.
Operators learn which alarms they can ignore. Then a real problem looks the same as a sensor that beeps for two seconds and clears itself.
When every alarm looks equally urgent, people stop using the list. New alarms keep getting added, but fewer people walk out to the machine to check them.
Alarms
A long alarm list does not tell you where to go
How long
A two-second beep should not look like 40 minutes out of limit
People on the shift focus on the long ones. Those are still out of limit when someone looks at the screen.
The short ones still count. A jam that clears in two seconds is easy to skip once. Two hundred of them on one line is more than an hour, and that hour never shows up if each alarm is only stored as "it happened." That lost time is the same problem as micro-stops.
A 40-minute alarm is what the shift sees on the screen. The two-second ones disappear unless you add them up.
Clean up the noisy alarms before you add another one
Alarms people ignore
- A two-second stop and a 40-minute alarm look the same if you only store that it happened.
- You cannot tell how long the value was out of limit.
- The limits live in a spreadsheet, separate from the PLC tag.
- Night shift clears the alarm, and day shift never looks at what was cleared.
Alarms people use
- Warning and critical are marked on the same point as the limit.
- You can see how long the value has been out of limit, and when it first tripped.
- The alarm is tied to the same machine and line as the tags you already log.
- The email goes to the people who own that machine.
Use the limits you already trust
Setpoint can raise alarms from the limits on your equipment model and show how long each point has been out of limit.
Setpoint
Show how long each point has been out of limit
Setpoint compares live values with the limits on each Blueprint detail. The alarm list shows whether it is a warning or a critical alarm, and how long the value has been out of limit. You can email the people who own that group of equipment.
A separate note tells you when logging stopped, so a dead logger does not get lost in the process alarm list. If that limit is why the line stopped, you use the same history to count downtime cost.
See Setpoint on a line like yours
Book a demo with Nick’s team, or start a Pilot with a configured edge device.